MA2000 Endoscopic Surgical System

MA2000 Endoscopic Surgical System consists of a surgeon console, a patient surgical platform, and an imaging processing platform. The master control arms of the surgeon console are lightweight and agile, combined with an immersive 3D viewer to provide doctors with an intuitive and focused operating experience. The slender surgical instruments minimize trauma, while the flexible wrist joints exceed the dexterity of the human hand, meeting the demands of delicate operations and assisting surgeons in tackling highly complex procedures. The 3D stereoscopic imaging provides rich depth information, making surgical operations safer and more efficient. The master-slave control system enables high-precision control at various scaling ratios while eliminating hand tremors, allowing for smooth and precise surgical maneuvers and offering significant clinical advantages.

+88-01924400748

Call for orders or any information.

Product Description

  1. SYSTEM OVERVIEW
PARAMETER TECHNICAL SPECIFICATION
Product Type Robotic Laparoscopic Surgical System
System Architecture Integrated multi-component robotic surgical platform
Primary Configuration Surgeon Console + Patient Cart + Imaging Cart
Surgical Approach Minimally Invasive / Laparoscopic Surgery
Robotic Configuration Four-arm suspension boom design
Control Concept Surgeon-controlled robotic manipulation
System Design Ultra-high integration design
Primary Objective High-precision instrument manipulation, enhanced visualization and improved surgical ergonomics

 

  1. SURGEON CONSOLE
PARAMETER TECHNICAL SPECIFICATION
Console Type Immersive surgeon console
Visualization Immersive 3D visualization
Ergonomics Ergonomic operating posture designed to reduce surgeon fatigue
Surgeon Control Master controller-based robotic manipulation
Control Precision Fine robotic instrument control
Force Feedback Master controller with two-stage force feedback
Force Sensing Embedded force sensor
Visual Interaction Immersive 3D monitor
Image Interaction Digital zoom, dynamic dimming and touchscreen marking
Shared Visualization Interactive shared-view capability

 

  1. PATIENT CART & ROBOTIC ARMS
PARAMETER TECHNICAL SPECIFICATION
Number of Robotic Arms 4
Arm Configuration Four-arm suspension boom
Degrees of Freedom 13 DoF per robotic arm
Arm Swing Range Up to 340°
RCM Motion Range Up to 300°
Positioning One-click positioning
Arm Movement Expanded motion space and maneuverability
Collision Management Intelligent collision avoidance / spatial adjustment
Instrument Arrangement Multiple robotic instruments simultaneously supported
Platform Suspended rotating platform

 

  1. ROBOTIC INSTRUMENT SYSTEM
PARAMETER TECHNICAL SPECIFICATION
Instrument Type Robotic laparoscopic surgical instruments
Instrument Design Lengthened / extended surgical instruments
Instrument Reach Extended reach for complex surgical procedures
Deep Pelvic Surgery Designed to facilitate access in deep pelvic procedures
High-BMI Procedures Extended instruments intended to reduce limitations associated with instrument length
Instrument Portfolio 15 specialized surgical instruments
Instrument Integration Compatible with four-arm robotic configuration

 

15 Specialized Instruments:

  • Monopolar Curved Scissors
  • Fenestrated Forceps
  • Needle Driver
  • Monopolar Hook
  • ProGrasp Fenestrated Forceps
  • Large Needle Driver
  • Monopolar Cautery Spatula
  • Graspers
  • Scissors Needle Driver
  • Maryland Bipolar Forceps
  • Myoma Forceps
  • Large Scissors Needle Driver
  • Fenestrated Bipolar Forceps
  • Intestinal Forceps
  • Ultrasound Scalpel
  1. ULTRASONIC SURGICAL INSTRUMENT
PARAMETER TECHNICAL SPECIFICATION
Instrument Ultrasonic Scalpel
Length 54 cm
Design Extended-length surgical instrument
Purpose Facilitate access during procedures requiring extended instrument reach
Length Matching Designed with similar length to other robotic instruments to avoid instrument length mismatch

 

  1. IMAGING SYSTEM
PARAMETER TECHNICAL SPECIFICATION
Imaging Technology 3D 4K fluorescence imaging
Endoscope 3D 4K fluorescence endoscope
Image Resolution Class 4K
Image Dimension 3D
Fluorescence Capability Integrated fluorescence visualization
Fluorescence Colors 5 Types
Latency Ultra-low latency imaging
Startup Latency ≤70 ms
Color Processing Adaptive image colour adjustment
Brightness Processing Adaptive image brightness adjustment
Display Immersive 3D monitor
Image Presentation Dual-scan display
Digital Zoom Available
Dynamic Dimming Available
Image Marking Touchscreen marking

 

  1. IMAGING CART & ASSISTANT DISPLAY
PARAMETER TECHNICAL SPECIFICATION
Cart Type Dedicated Imaging Cart
Monitor HD touchscreen monitor
Monitor Function Surgical assistant observation and operation
Image Processor Integrated image processing system
Image Adjustment Adaptive colour and brightness adjustment
Touchscreen Functions Image marking
Picture-in-Picture Supported
Digital Zoom Supported
Dynamic Dimming Supported
Shared View Interactive shared-view functionality

 

  1. MOTION, RCM & POSITIONING TECHNOLOGY
PARAMETER TECHNICAL SPECIFICATION
Robotic Arm Swing 340°
RCM Joint Range 300°
Degrees of Freedom 13 DoF per robotic arm
Robotic Arms 4
Patient Cart Platform Suspended rotating platform
Positioning One-click positioning
Coverage 270° illustrated coverage

 

  1. SAFETY & CONTROL TECHNOLOGY
PARAMETER TECHNICAL SPECIFICATION
Dual Encoder Cross Verification Real-time position/movement verification
Collision Avoidance Intelligent spatial collision management
RCM Spatial Adjustment Controlled robotic movement around the surgical access point
Force Sensor Embedded force sensing
Force Feedback Two-stage force feedback
UPS Protection Multiple UPS protection
Power Continuity Designed to maintain continuous power supply
System Integration Reduced connectivity requirements

 

  1. IMAGE PROCESSING & VISUALIZATION
PARAMETER TECHNICAL SPECIFICATION
Adaptive Colour Adjustment Automatic adjustment of image colour characteristics
Adaptive Brightness Adjustment Dynamic adjustment of image brightness
Digital Zoom Enlarged visualization of the surgical field
Dynamic Dimming Adjustment of display brightness
Touchscreen Marking Allows visual marking/annotation
Dual-Scan Display Enhanced image presentation / colour reproduction
Ultra-Low Latency Minimizes delay between imaging and display
Picture-in-Picture Secondary image/information display capability

 

  1. DEEP PELVIC & HIGH-BMI APPLICATION
PARAMETER TECHNICAL SPECIFICATION
Instrument Design Lengthened robotic surgical instruments
Trocar Interference Extended instruments designed to reduce trocar interference
Deep Pelvic Procedures Improved access for deep pelvic procedures
High-BMI Patients Extended reach for procedures involving high-BMI patients
Ultrasonic Scalpel 54 cm extended-length ultrasonic scalpel

 

  1. COMPLETE SYSTEM CONFIGURATION
PARAMETER TECHNICAL SPECIFICATION
A. Surgeon Console Immersive 3D monitor; ergonomic surgeon workstation; master controllers; two-stage force feedback; robotic control interface
B. Patient Cart Four robotic arms; suspended rotating platform; 13 DoF per arm; RCM spatial adjustment; one-click positioning; intelligent collision avoidance
C. Imaging Cart 3D 4K fluorescence imaging; 3D 4K fluorescence endoscope; image processor; HD touchscreen; PIP; digital zoom; dynamic dimming; touchscreen marking
D. Robotic Instruments 15 specialized surgical instruments; extended-length instruments; ultrasonic scalpel; monopolar, bipolar, grasping, cutting and needle-driving instruments

 

  1. KEY TECHNICAL PARAMETERS – SUMMARY
PARAMETER TECHNICAL SPECIFICATION
System Torin® Laparoscopic Surgical Robot
Robotic Arms 4
Degrees of Freedom 13 DoF per robotic arm
Arm Swing Range 340°
RCM Motion Range 300°
Imaging 3D 4K Fluorescence
Endoscope 3D 4K Fluorescence Endoscope
Main Display Immersive 3D Monitor
Assistant Display HD Touchscreen
Force Feedback Two-stage
Force Sensor Embedded
Encoder Safety Dual Encoder Cross Verification
Power Protection Multiple UPS Protection
Instrument Portfolio 15 Specialized Instruments
Ultrasonic Scalpel 54 cm
Patient Cart Suspended Rotating Platform
Positioning One-click
Instrument Design Lengthened / Extended
System Design Ultra-high Integration
Primary Application Laparoscopic / Minimally Invasive Surgery

 

  1. TECHNICAL NOTE

The specifications above are based on the information shown in the supplied Torin® Laparoscopic Surgical Robot brochure. Where the brochure does not provide a numerical or engineering value, no value has been invented. Items such as electrical rating, power consumption, monitor dimensions, frame rate, optical magnification, trocar diameter, instrument shaft diameter, sterilization parameters, system dimensions, system weight, operating/storage temperature and regulatory certifications should be confirmed from the manufacturer’s official technical datasheet before inclusion as mandatory tender specifications.